Micromeds

Micromed I
Micromed I +
Micromed II +
Micromed III

Micromed I

micromed I Verastile
For use with any standard, inexpensive I.V. solution set
Cost Effective
No Hidden extra disposable or running costs
Friendly
Easy to set up - just enter the drop rate and the controller does the rest
Flexible
Very wide flow range - between 2 and 240 drops per minute
Accurate
+/- 2% of selected drop rate
Safe
Gravity system, as recommended by regulatory bodies in the UK. No positive pressure hazards as associated with pumps. Tamper-proof, fail-safe and battery backup
Informative
Total volume infused and comprehensive alarm systems including open door alarm
Considerate
No false alarms, silent running, easy to clean and maintain, small and light
Approved
British Standard BS 5724 / IEC 601 - 1 and British Department of Health

[top]

Micromed I +

micromed IplusVerastile
For use with any standard, inexpensive I.V. solution set
Cost Effective
No Hidden extra disposable or running costs
Friendly
Easy to set up - just enter the flow rate and the controller does the rest
Flexible
Very wide flow range - between 5 and 800 millilitres per hour (ml/hr)
Accurate
+/- 5% of selected drop rate
Safe
Gravity system, as recommended by regulatory bodies in the UK. No positive pressure hazards as associated with pumps. Tamper-proof, fail-safe and battery backup
Informative
Total volume infused and comprehensive alarm systems including open door alarm
Considerate
No false alarms, silent running, easy to clean and maintain, small and light
Approved
British Standard BS 5724 / IEC 601 - 1 and British Department of Health

[top]

Micromed II +

micromed IIplusVerastile
For use with any standard, inexpensive I.V. solution set
Safe
Gravity system, as recommended by regulatory bodies in the UK. No positive pressure hazards as associated with pumps. Tamper-proof, fail-safe and battery backup
Friendly
Easy to set up , infusion volume and time are entered as prescribed, no complicated calculations for nursing staff
Flexible
Very wide volume range (5-3000ml)
Very wide flow range equivalent to 1.3 - 240 drops/minute (4.5 - 800 ml/hour for a 20 drops/ml giving set)br>
Accurate
+/- 5% of total volume delivered. Automatic compensation for increase in drop size with rate
Cost Effective
No Hidden extra disposable or running costs
Informative
Remaining infusion time and volume infused. Comprehensive alarm system including open door, pre-end and end of run alarms
Considerate
No false alarms, silent running, easy to clean and maintain, small and light
British made and Approved
British Standard BS 5724 / IEC 601 - 1 and British Department of Health

[top]

Micromed III

micromed IIIUniversal
For use with any standard, inexpensive I.V. solution and any I.V. giving set
Safe
Gravity system, as recommended by regulatory bodies in the UK. No positive pressure hazards as associated with pumps. Tamper-proof, fail-safe and battery backup
Friendly
Easy to set up , infusion volume and time are entered as prescribed, no complicated calculations for nursing staff
Flexible
Very wide volume range (1-3000ml)
Very wide flow range equivalent to 1.3 - 240 drops/minute (4.5 - 800 ml/hour for a 20 drops/ml giving set)
Accurate
+/- 5% of total volume delivered. Automatic compensation for increase in drop size with rate
COST Effective
No Hidden extra disposable or running costs
Informative
Remaining infusion time and volume infused. Comprehensive alarm system including open door, pre-end and end of run alarms
Considerate
No false alarms, silent running, easy to clean and maintain, small and light
British made and Approved
British Standard BS 5724 / IEC 601 - 1 and British Department of Health

[top]